AP110002 OPERATION
TRANSPORTING THE DRYMAX:
The Cromtech Drymax Carpet Dryer is designed to be stacked vertically or horizontally for transport.
ELECTRICAL REQUIREMENTS:
The Carpet Dryer can be plugged directly into any standard wall receptacle. Without ducting, the
Carpet Dryer will draw 1.9 amps. Ducting will reduce amp draw. Up to 6x Carpet Dryers can be daisy
chained on a standard 15-amp branch circuit.
DUCTING
The lip on the exhaust opening of the Carpet Dryer is designed to accommodate lay flat ducting with
14” or larger diameter.
RESETTABLE CIRCUIT BREAKER
The 10 amp circuit breaker protects the unit and devices connected to it. In case of a fault, the
breaker can be reset at the Carpet Dryer control panel.
Use of multiple fans and any other connected devices must be in accordance with the National
Electric Code and any additional codes or laws required by your local government.
IMPORTANT: Total amperage of the Carpet Dryer plus all devices plugged into its convenience
receptacle is limited by the onboard circuit breaker. Excessive current will cause the circuit breaker
to trip. This may occur instantly or after a while depending on the operating conditions.
IMPORTANT: When the Carpet Dryer is plugged into a standard “powered” wall outlet the Carpet
Dryer’s duplex outlet is electrically “HOT” and AC voltage is present.