AS110001 CROMTECH™ AIR SCRUBBER
CAUTION: Risk of electric shock. Can cause injury or death.
NOTE: Remove foam cap before use
To reduce the risk of electric shock:
• Do not expose to standing water or rain
• Connect to GFCI outlet
• Do not use an extension cord
• Unplug fan before servicing or changing filters.
• Do not block air intake or outlet. One foot
minimum distance to obstructions.
• Indoor use only
• Do not use as stool or bench
• Do not operate with damaged cord or plug.
• Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar
• coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic
area and where it will not be tripped over.
TRANSPORTING THE AIR SCRUBBER:
The Air Scrubber should be transported vertically or horizontally on the appropriate feet
located on the bottom of the unit or opposite the handle
ELECTRICAL REQUIREMENTS:
The Air Scrubber can be plugged into a grounded 15 Amp circuit. It draws 2 Amps with clean filters
and no ducting. The amp draw will decrease slightly with added ducting and as the filters load with
particulate. Due to the presence of GFCI receptacle, the Pro model must be plugged directly into a
wall outlet. No extension cords should be used.
AIR DUCTING:
A. Inlet Ducting - Occasionally the area to be filtered is difficult to access and/ or the unit
cannot be in the area. In such cases, the air can be ducted to the unit's inlet. A round 16"
diameter flexible duct can be attached to the unit inlet. It connects by placing the wire in the
duct over the duct collar lip at one location and working over it over the lip gradually. It may
be removed after use for easier transport and storage.
B. Outlet Ducting - A detachable shaped exhaust ring is supplied that will allow 10" round lay-
flat plastic duct to be attached to the Air Scrubbers outlet. Put the plastic duct end through
the inside of the ring. Roll the duct end outward so that it over-laps the outside of the ring.
Clip the ring back onto the exhaust grill.
C. Negative Air Ducting - On the Air Scrubber can be used to filter and exhaust air from a
space. When exhausting to outside the space, the space will be under a slight negative
pressure. This will help prevent airborne particles from leaving the space, because the
negative pressure will draw air in through openings in the space's exterior surfaces.