Connector X22 DIO
Pin
Port
Default Signal Type
Other Configurations
DIN M12
female, 5-pole
X22.1
-
+24 V Sensor Supply 1
X22.2
9
Digital Output
Digital Input
X22.3
-
GND
X22.4
10
Digital Output
Digital Input, Pulse Counter
Input
X22.5
-
GND
Connector X23 DIOP
Pin
Port
Default Signal Type
Other Configurations
DIN M12
female, 5-pole
X23.1
-
+24 V Sensor Supply 2
X23.2
45
Digital Output
Digital Input, PWM Output
X23.3
-
GND
X23.4
46
Digital Output
Digital Input, PWM Output
X23.5
-
GND
Connector X24 DIO
Pin
Port
Default Signal Type
Other Configurations
DIN M12
female, 5-pole
X24.1
-
+24 V Sensor Supply 1
X24.2
21
Digital Output
Digital Input
X24.3
-
GND
X24.4
22
Digital Output
Digital Input
X24.5
-
GND
Connector X25 DIO
Pin
Port
Default Signal Type
Other Configurations
DIN M12
female, 5-pole
X25.1
-
+24 V Sensor Supply 2
X25.2
35
Digital Output
Digital Input
X25.3
-
GND
X25.4
36
Digital Output
Digital Input
X25.5
-
GND
For a complete list of I/O ports, including internal ports 58 to 63, see Appendix 2.
It is not possible to combine a Digital Output with a PWM in the same connector. If any of the ports
in a connector is configured as digital out, the other one will also work as digital out even if it is
configured as PWM.
Notice that the connector descriptions are those which are located on the unit, not those that the
attached cables shall have in order to mate with them.
Use caution when plugging/unplugging connectors. If the pins become bent or damaged they may
not function correctly, or in the worst case, CrossFire GX1 or other equipment may be damaged.