EasyManua.ls Logo

Crossfire GX1 - Digital Input Signal Configurations

Crossfire GX1
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CrossFire GX1
Date: Apr 26, 11
Manual and reference handbook
www.crosscontrol.com
19
PWM Outputs
Port
Signal Type
Channel
Comment
11
PWM Output
B
Interface: DIOP
12
PWM Output
A
13
PWM Output
B
14
PWM Output
A
15
PWM Output
B
16
PWM Output
A
17
PWM Output
B
18
PWM Output
A
27
PWM Output
B
28
PWM Output
A
29
PWM Output
B
30
PWM Output
A
31
PWM Output
B
32
PWM Output
A
45
PWM Output
B
46
PWM Output
A
PWM Output Electrical Characteristics
Signal Name
Parameter
Value
Unit
Comment
Min
Typ
Max
PWM Output
Output Voltage
0
24
36
V
Note: Unregulated
Over/Under Voltage
Protection
-39
39
V
Zener diode
Output Current
0.05
2
A
Short-Circuit indication
VIA LED Indication, See
ch 2.3.12
Time Constant
1.5
ms
C
Resolution
0.4
%
Approx. 10 bits 0 to 1275
in 5 Hz steps
7.3. Digital Inputs
There are five types of Digital Inputs on the CrossFire GX1. Every port on the unit is capable of
being configured as a Digital Input (with the exception of Ports 2, 4, 6, 38, 40, 42) provided that the
ports are not already configured as something else.
For best results, the installation of the CrossFire GX1 should be such that the Digital Inputs are
matched with the type of signal source.
For high-side drivers or open emitter, open source: hook up to Digital Inputs with pull-
down resistors
For low-side drivers, open collector, open drain: hook up to Digital Inputs with pull-up
resistors
For bipolar, totem-pole or “push-pull” signals, use either of the above types, or floating
inputs