8. Appendix 1 Environmental Tolerances
Environmental Tolerances
Environmental Test
Level
Standard
High temperature
Functional During test
+70 °C, 24 hours
IEC 60068-2-2 Bd
Low temperature
Functional During test
-40 °C, 24 hours
IEC 60068-2-1 Ad
Shock
Functional During test
30 g / 6 ms
6 impulses in 6 directions
IEC 60068-2-27
Vibration
Sinus:
Functional test during test
Random:
Functional test during test
5-1000 Hz, 1 oct / min
5 -11.5 Hz ± 7.5 mm
11.5-1000 Hz 4 g
3 directions, 10 double sweeps/dir.
5-199 Hz 0.03 g2 / Hz
200-399 Hz 0.02 g2 / Hz
400-599 Hz 0.01 g2 / Hz
600-1000 Hz 0.005 g2 / Hz
3.72g (RMS)
3 directions x 1h
IEC 60068-2-6
IEC 60068-2-64
Electrical Transients
Conducted transients
Pulse 1: -50 V
2: +25 V
3a: -220 V
3b: +220 V
4: -5 V
5: +70 V
ISO 7637-2
EMC Susceptibility
(Component)
RF electromagnetic field
200 1000 MHz
30 V/m
1 kHz sine
ISO 11452-2
Bulk Current Injection
20 200 MHz
60 mA
1 kHz sine
ISO 11452-4
EMC Emissions (Component)
Frequency
MHz
30-75
75-400
400-1000
Narrowb.
dBmV/m
54-44
44-55
55
Broadb.
dBmV/m
64-54
54-65
65
EN 13 309
Electrostatic Discharge
+/- 4 kV air/contact
ISO/TR 10605
Enclosure
IP67
IEC 60529