27
Table 3 Charge Mode Specifications
Utility Charging Mode
INVERTER MODEL X-3KVA-M
Charging Algorithm 3-Step
AC Charging Current (Max) 25Amp(@V
I/P
=230Vac)
Bulk Charging
Voltage
Flooded Battery 29.2
AGM / Gel Battery
28.2
Floating Charging Voltage 27Vdc
Charging Curve
Time
Battery Voltage
, per cell
Charging Current, %
100%
50
%
Bulk
(Constant Current)
Absorption
(Constant Voltage)
Maintenance
(Floating)
Current
Voltage
T1
T
1
=
10*
T0
,
minimum 10
mins
, maximum
8hrs
T
0
2.
43Vdc
(
2.
35Vdc
)
2.25Vdc
MPPT Solar Charging Mode
Charging Current
40Amp
PV Array MPPT Voltage Range
30~80Vdc
Max. PV Array Open Circuit Voltage
102Vdc
Max Charging Current
(AC charger plus solar charger)
60Amp
Table 4 General Specifications
INVERTER MODEL X-3KVA-M
Operating Temperature Range -10°C to 50°C
Storage temperature -15°C~ 60°C
Humidity
5% to 95% Relative Humidity (Non-condensing)
Dimension (D*W*H), mm 88 x 257.6 x 320
Net Weight, kg 5.9