EasyManua.ls Logo

Crown 1160A - Back Panel Controls and Connectors

Crown 1160A
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commercial Audio Series Amplifiers
page 8
Operation Manual
A
B
C
D
F
E
D. Amp Input Connector
3-pin Phoenix-type, high-impedance balanced, one per
amplifier channel.
E. AC Power Inlet
Detachable IEC.
F. Output VCA Connector
One for every two channels, 4-pin Phoenix-type connector
for two VCA control lines of +10 VDC and ground. Compati-
ble with Crown 1-VCAP and 4-VCAP modules.
1.4 660A Back Panel Controls and Connec-
tors
A. Reset Switch
Resets the circuit breaker that protects the power supply. 220/
230/240V units have a fuse instead.
B. Amplifier Outputs Connector
One 4-position terminal strip for channels 5 and 6 including
COM and 4-ohms terminals for each channel. Accepts up to
10 AWG terminal forks.
C. Amplifier Outputs Connectors
One connector per channel for channels 1-4 including COM,
4-ohms, 70V and 100V terminals. Accepts up to 10 AWG ter-
minal forks.Non-touch cover included.