Dry Contact Signal
There is one dry contact (3A/250VAC) available on the rear panel. It could be used to deliver signal to external
device when battery voltage reaches warning level.
Unit Status Condition
Dry contact port:
NC & C NO & C
Power Off Unit is off and no output is powered. Close Open
Power On
Output is
powered
from Battery
power or
Solar energy.
Program 01
set as USB
(utility first)
Battery voltage < Low DC
warning voltage
Open Close
Battery voltage > Setting
value in Program 13 or
battery charging reaches
floating stage
Close
Open
Program 01 is
set as SBU
(SBU priority)
Battery voltage < Setting
value in Program 12
Open
Close
Battery voltage > Setting
value in Program 13 or
battery charging reaches
floating stage
Close Open
OPERATION
Power ON/OFF
Once the unit has been properly installed and the batteries are connected well, simply press On/Off switch
(located on the display panel) to turn on the unit.
Inverter Turn-on
After this inverter is turned on, WELCOME light show will be started with RGB LED BAR. It will slowly cycle
through entire spectrum of nine colors (Green, Sky blue, Royal blue, Violet, Pink, Red, Honey, Yellow, Lime
yellow) about 10-15 seconds. After initialization, it will light up with default color.
RGB LED BAR can light up in different color and light effects based on the setting of energy priority to display
the operation mode, energy source, battery capacity and load level. These parameters such as color, effects,
brightness, speed and so on can be configured through the LCD panel. Please refer to LCD settings for the
details.