19
11
Maximum utility charging
current
Note: If setting value in
program 02 is smaller than
that in program in 11, the
inverter will apply charging
current from program 02 for
utility charger.
30A (default)
Setting range is 2A, then from
10A to 100A. Increment of each
click is 10A.
12
Setting voltage point or SOC
back to utility source when
selecting “SBU” (SBU
priority) in program 01.
23V (default)
Setting range is from 22V to 25.5V.
Increment of each click is 0.5V.
SOC 10% (default for
Lithium)
If any types of lithium battery is
selected in program 05, setting
value will change to SOC
automatically. Adjustable range is
5% to 95%.
13
Setting voltage point or SOC
back to battery mode when
selecting “SBU” (SBU
priority) in program 01.
Setting range is from 24V to 29V. Increment of each click is 0.5V.
Battery fully charged
27V(default)
SOC 30% (default for
Lithium)
If the battery type (#05) set as
Lithium, this setting will change to
SOC automatically. Adjustable
range is 10% to 100%. Increment
of each click is 5%.
16
Charger source priority:
To configure charger source
priority
If this inverter/charger is working in Line, Standby or Fault mode,
charger source can be programmed as below:
Solar first
Solar energy will charge battery as
first priority.
Utility will charge battery only
when solar energy is not available.