44
Table 3 Charge Mode Specifications
Utility Charging Mode
INVERTER MODEL X-4KW-M
Charging Algorithm 3-Step
AC Charging Current (Max)
100Amp
(@V
I/P
=230Vac)
Voltage
Flooded Battery 29.2Vdc
AGM / Gel Battery 28.2Vdc
Floating Charging Voltage 27Vdc
Charging Curve
Time
Battery Voltage,
per cell
Charging Current
, %
100%
50%
Bulk
(Constant Current)
Absorption
(Constant Voltage)
Maintenance
(Floating)
Current
Voltage
T
1
T1 = 10* T0, minimum 10mins, maximum 8hrs
T
0
2
.
43Vdc (2.35Vdc)
2.25Vdc
MPPT Solar Charging Mode
INVERTER MODEL
X-4KW-M
Max. PV Array Power
5000W
Nominal PV Voltage
320Vdc
Start-up Voltage
150Vdc +/- 10Vdc
PV Array MPPT Voltage Range
120~450Vdc
Max. PV Array Open Circuit Voltage
500Vdc
Max Charging Current
(AC charger plus solar charger)
120Amp
Table 4 General Specifications
INVERTER MODEL X-4KW-M
Operating Temperature Range -10°C to 50°C
Storage temperature -15°C~ 60°C
Humidity
5% to 95% Relative Humidity (Non-condensing)
Dimension (D*W*H), mm 115 x 300 x 400
Net Weight, kg 9