POWER PACK
(Ensure good ven
CELL HOUSING
RETURN
TO POOL
PUMP
FROM
SKIMMER BOX
FILTER
POWER
WARNING: DO NOT plug in if carton has been wet.
4. POWER PACK AND CELL INSTALLATION
9
4.3 Installation Diagram
ALWAYS ensure that pipe work and equipment do not allow gases generated from the cell to collect and
build up in any part of the installation.
It is RECOMMENDED that the Cell Housing be installed horizontally to create a natural gas trap that acts as
a safety device. Installation in any other way may cause explosion, injury or death if the installer does not
allow for gas removal. A venturi pipe is installed/moulded within the Cell Housing design to eliminate any
possible gas build up, although it is always recommended to ensure proper installation to eliminate this
from happening.
The Cell Housing must be installed in the RETURN pipework to the pool. It must always be installed after
, gas heater, solar heating or heat pump.
DO NOT
ell Housing, it is not needed and may react with the plastic.
Saltwater may damage electrical components in the Power Pack.
WARNING:
Important Notes:
The pump rating must not exceed 8amps.
We DO NOT recommend the use of valves on the inlet or outlet of the cell housing. If you do use a valve
then it is important to ensure that the valve cannot deadhead (lock closed) while the pump is running. It is
the installers responsibility to ensure some f
w control is installed in this instance and it disables
the pump.