12
Master Programming Mode
Master Programming Mode
To enter Master Programming Mode, press and hold both buttons for 5 seconds.
Note: All Master Programming functions have been preset at the factory. Unless a change is desired, it is NOT
necessary to enter Master Programming Mode.
1. Regeneration Time ( r ) Example [ r 2A ]
- The time of day at which regeneration may take place is designated by the letterr”.
- Default regeneration time setting for SOFTENERS is 2a
- The rst display digit indicates A.M. or P.M. To change the value, press the Set/Change button.
- Press Menu/Enter button to accept the value and move to the next digit.
- The second and third display digits indicate the hour at which the regeneration will occur.
- Change the digits with the Set/Change button and accept with the Menu/Enter button.
- After the entire display ashes, press the Menu/Enter button to move to the next menu item.
2. Regeneration Day Override (A)
- Press Menu/Enter button. This display is used to set the maximum amount of time (in days) the unit can be
in service without regeneration. This setting is identied by the letter “A” in the left digit. Regeneration will
begin at the scheduled time. A setting of zero will cancel this feature.
- Example: Override every 7 days (A-07), default setting, or cancel setting (A-00). Maximum is 29.
3. Regeneration Cycle Step Times (Steps 1, 2, 3, 4)
Example [ 3 - 10 ]
- The next 4 displays set the duration of time in minutes for each regeneration cycle step.
- The step number which is currently modiable is indicated on the far left of the display screen.
- The number of minutes allotted for the selected backwash step is displayed on the far right.
- Change the digit values using the Set/Change and Menu/Enter buttons as described above.
Warning : Do not reduce salt settings below 9 lbs. as the water level in the brine tank will not reach the grid plate.
4. System Capacity in Grains ( c )
- Press the Menu/Enter button. This display is used to set the system capacity in grains and is used in
conjunction with the hardness setting to calculate total gallons of treated water available between regen
erations. This option is identied by the letter “c” in the left digit.
The maximum value for this item is 399. Example: 32,000 grain capacity ( c 032 ).
5. Reserve Capacity Setting % Example (p - 25)
6. Bluetooth Enabled BE - 1 (ON)
BE - 0 (OFF)
7. Bluetooth Password BBPP is displayed for one second, then password is displayed.
8. To Exit the Master Programming Mode, press the Menu/Enter button until time of day returns.
Note: If no buttons are pressed for 60 seconds, the Master Programming Mode will be exited automatically.