EasyManua.ls Logo

CSI CM24 - Start Up Procedure; Initial Settings and Configuration; Step-by-Step Startup Process; Filling the Brine Tank with Salt

CSI CM24
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
1. Set time of day.
2. Set a.m. or p.m.
3. Set water hardness in grains per gallon (gpg).
Note: If the water contains iron and / or manganese, multiply the total parts per million (ppm) by “four” (4) and then
add to the grains per gallon (gpg) of hardness. Use this COMPENSATED HARDNESS level when programming
the regeneration frequency.
1. Set regeneration day override if other than (7) days is desired. (This is particularly useful when iron is being treat
ed to prevent fouling of the resin.)
2. Set regeneration time, if other than 2:00 a.m. is desired.
-Start Up Procedure-
1. Put unit in bypass using the handles behind the control valve.
2. Start a regeneration by pressing and holding the set change button for 3 seconds.
a. The display may show zeros or a 1, repeat holding the set change button.
3. Display on unit should read 1-10 (Step 1-10 min). Very slowly open the inlet bypass to remove any remaining
air.
4. After the inlet bypass has been fully opened slowly, open the outlet bypass and let unit backwash for 2 min
utes or until water is clear. Verify water is going to drain.
5. Fill the brine tank with a 5-gallon bucket of water and add the provided Sani pack.
a. If you have already added salt, then pour the water and Sani pack down the white 4in brine well
cylinder.
6. Advance unit to next regeneration cycle (Step 2-Brine draw) by holding the set change button for 3 seconds.
7. Stay in (step 2- Brine draw) for an additional 10 minutes and verify all water has been drawn out of the brine
tank.
8. Advance unit to next regeneration cycle (Step 3-Rapid Rinse) by holding the set change button for 3 seconds.
Stay in this step for 2 minutes. Verify water is going to drain.
9. Advance unit to next regeneration cycle (Step 4- Brine ll) by holding the set change button for 3 seconds.
Let this step continue until minutes remaining are zero and the time of day appears on display.
a. When nished the brine tank should have water above the salt grid.
10. Lastly add salt to the brine tank. Do not ll salt higher than the brine well.
- Filling The Brine Tank With Salt -
To expect a high level of performance and reliability, a salt manufactured specically for water softeners must be
used. Salt of this grade is virtually free from dirt and other particulates that would eventually cause the softener to
malfunction. A pellet type salt is recommended, although any high quality water softener salt (such as solar salt) will
sufce. If iron is present in raw water, use of iron inhibiting salt is recommended. The salt level will decrease after
each regeneration cycle. Consequently, the salt compartment will need to be checked and replenished periodically.
1. Fill the salt compartment with water softener salt as described above. This will be approximately 150 pounds of
salt.
Warning : Do not ll salt above level of the brine well.
2. Close cabinet brine tank lid.
Start Up Procedure