3. Fixed Channel is the specific frequency channel to be used when Frequency Order is set
to Fixed.
4. Power is the conducted power entering the antenna, the value is 10 times the dBm
value desired. For example, 300 means 30 dBm. i.e. (300/10) dBm.
5. Tag Population is the approximate number of tags to be typically inventoried.
6. The Q Override value is automatically set when you enter the Tag Population value. This
value can be overwritten by pressing the “Override” button and editing the Q value. To
return to the default value, press ‘Reset’ Appendix D describes this in detail.
7. Session is the EPC defined session for querying the tags. For detailed explanations of
Session please refer to Appendix C.
8. Target is the EPC defined query target of the tag status flag, A, B, or A/B Toggle. For a
detailed explanation of Target. Please refer to Appendix F
9. Query Algorithm is either DynamicQ or FixedQ. A detailed explanation is found in
Appendix E.
10. Reader Mode or Link Profile is either 0, 1, 2, or 3. Detailed explanation is found in
Appendix B.
After changing parameters, press “SAVE” button. A beep will confirm the successful save.