97
easier management at sites where you have multiple CS108 units. After the name is
changed, you need to power off and power on the CS108 for the name to be effective.
3. Battery Level Format defines how you want to view the battery level, either in absolute
voltage or in percentage.
4. Inventory Alert Sound enables or disables the sound during inventory. During inventory,
there are 2 different pitches of sound: high pitch means a new unique tag has been read.
Low pitch means a tag that has been read before has been read again. Also, the rate of
beeping is proportional to the rate of tag reads received.
5. Inventory Delay Time is an internal data control. Do not change.
6. Barcode Reset to Continuous Mode is a special function button to reset the barcode to
continuous mode. This button may need to be pressed after firmware upgrades and is an
artifact of this being Demo software for both users and developers. If the barcode has been
inadvertently set to trigger mode, this button resets it.
7. Reset Software/Reader to Default Setting is a special function button to reset the
configuration setting to the default values.
8. Get Serial Number gets the Product Serial Number. It is also on the paper label on the back
of the reader.
9. Shortcut defines the short cut sled trigger timing. The values are in msec. This is short cut
method to select either RFID inventory or barcode reader. When the user is in the main
page already, then this short cut trigger control will work. In this default setting, if the user
continuously presses the trigger for 0 to 500 msec and then releases it, he will jump to the
RFID inventory page. If he keeps on pressing the trigger past 500 msec and releases it
before 10,000 msec (10 seconds), then he will jump to the barcode reading page. The Min
and Max value ranges are 0 and 30,000 msec (30 seconds).
10. The Save Button MUST be pressed to make value changes effective.