Chapter 6. SNMP Option
115
November 2001
Text 6:
LED Status:
Parameter
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Test Error Sub Alarm Sub SYNC Loss
Sub Signal Loss
Main Alarm Main SYNC
Loss
Main Signal
Loss
ETU01-A SMNP Trap codes
Code Error message Error status On/Off
0 Alarm Buffer Empty 0:None
1 Power Turn 1:On 2:Off
2 Main Link Signal Loss 1:On 2:Off
3 Main Link SYNC Loss 1:On 2:Off
4 Main Link AIS 1:On 2:Off
5 Main Link RAI 1:On 2:Off
6 Main Link MRAI 1:On 2:Off
7 Main Link BPV 0:None
8 Main Link Frame Slip 0:None
9 Main Link CRC4 Error 0:None
11 Sub Link SYNC Loss 1:On 2:Off
18 Data port FIFO Slip 0:None
22 Data port Baud Rate Failure 0:None
26 End of Alarm Buffer 0:None