Appendix B: Performance Monitor
130
November 2001
Long term interval (LONG SEC)
The number of 15-minute intervals in the powered-up period.
Performance Monitor Brief Table
Display Description Range
BPV Cnt The total number of BPV errors during the last second. The display is updated every second.
CRC-4 must be disabled.
0-65535
CRC4 Cnt The number of CRC error events recorded during the last second. The display is updated
every second. CRC-4 must be enabled.
0-1024
CURR ES Number of ES measured during the current 15-minute interval. The display is updated every
second.
0-900
CURR UAS Number of UAS measured during the current 15-minute interval. The display is updated
every second.
0-900
LONG ES Number of ES measured during the current powered-on interval. The display is updated
every 15 minutes.
0-65535
LONG UAS Number of UAS measured during the current powered-on interval. The display is updated
every 15 minutes.
0-65535
CURR SEC The time in seconds that expired from the start of the current 15-minute interval. The display
is updated every second.
0-900
LONG SEC The number of 15-minute intervals that expired from the start of the current powered-on
interval. The display is updated every 15 minutes.
0-65535