Instruction Booklet
ENGLISH
KHEOS PLUS
EN
Carefully read this use and maintenance manual before using the unit.
CTR S.R.L. Via T.ed E. Manzini n° 9, 43126 Parma (Italy)
Tel. +39 0521/957611 - Fax. +39 0521/957677
Internet:www.ctr-srl-com E-mail: info@ctr-srl.com
Revision number 1.0 code 330080 Date 08/02/2016

Questions and Answers

  • J
    Jacqueline PinedaAug 4, 2025
    What to do if my CTR Kheos Plus Industrial Equipment vacuum pump is not working?
    • A
      Andrew AndrewsAug 4, 2025
      If the vacuum pump on your CTR Industrial Equipment isn't working, there are several potential causes. First, there may be gas in the circuit, in which case you should perform a recovery phase. Second, check the power supply and fuses to ensure the pump is receiving power. Finally, the pump itself may be damaged and require replacement.
  • E
    ecastilloAug 14, 2025
    What to do if my CTR Industrial Equipment unit is not recovering?
    • P
      Paige WoodsAug 14, 2025
      If your CTR Industrial Equipment unit is not recovering, a possible cause is a blown fuse. Check the fuse in the recovery compressor/solenoid valve on the circuit board. Another potential cause is a damaged recovery compressor, which would need to be replaced.
  • R
    reneeriveraAug 22, 2025
    What to do if CTR Industrial Equipment shows error E4 - Vacuum time expired?
    • J
      Jessica JonesAug 23, 2025
      If your CTR Industrial Equipment displays error code E4, indicating that the vacuum time has expired, it means that the -0.75 Bar threshold cannot be reached. In this case, you should check the integrity of the system and connection pipes.

Summary

Warranty

Labelling

Symbols

Introduction

Spare parts

Information on obtaining and installing replacement parts for the unit.

List of functions

Describes the primary operations the unit can perform, such as recovery and vacuum.

Technical characteristics

Safety precautions

Work environment

Specifies requirements for the operational area, including lighting and ventilation.

Preliminary checks

Recommended checks to perform before starting the unit's operation.

Disposal of electrical material

Instructions for proper waste disposal of electrical and electronic components.

USE

Critical safety information regarding refrigerant handling and potential hazards.

Maintenance

Power supply

Handling and transport

Mechanical cylinder retainer

Explanation of the system used to secure the refrigerant cylinder during operation.

General operating rules

Main panel

Description of the control panel, including buttons, gauges, and indicators.

Operating phases

Overview of the sequence and flow of operations for optimal results.

Use

Automatic operation

RECOVERY operation

VACUUM operation

CAR CHARGING operation

Pipe draining procedure

Refrigerant topping-up

BOTTLE CHARGE operation

A;C SYSTEM FLUSHING

SERVICE menu

Operator service menu

Service functions accessible to trained operators for unit customization.

Service menu for Technical staff

Refrigerant transfer from unit to external container

Routine Maintenance

Refrigerant filter replacement

Step-by-step guide for replacing the unit's refrigerant filter.

Replacement Vacuum pump Oil

SD card database update

Printer (Optional)

Troubleshooting

List of error messages

Fuses

CTR Kheos Plus Specifications

General IconGeneral
BrandCTR
ModelKheos Plus
CategoryIndustrial Equipment
LanguageEnglish