2 / CULLIGAN MARK 10 AUTOMATIC WATER CONDITIONER
Specifications
Culligan
®
Mark 10 Automatic Water Conditioners
with Auto Clock or Soft-Minder
®
Meter
9" Model 12" Model
Control Valve 5-cycle, Reinforced Thermoplastic 5-Cycle, Reinforced Thermoplastic
Overall Conditioner Height 44 in (1118 mm) 44 in (1118 mm)
Media Tank Dimensions (Dia x Ht) 9 x 38 in (229 x 965 mm) 12 x 38 in (305 x 965 mm)
Salt Storage Tank Dimensions 16 x 43 in (406 x 1092 m) 16 x 43 in (457 x 1092 mm)
Exchange Media, Type and Quantity Cullex
®
Media, 0.7 cu ft Cullex Resin, 1.4 cu ft
(20 liters) (40 liters)
Underbedding Type and Quantity None None
Exchange Capacity @ Salt Dosage 15,500 grains (1 000 grams) 28,800 grains (1 866 grams)
Per Recharge
1
@ 4.0 lb (1.8 kg) @ 8.0 lb (3.6 kg)
20,300 grains (1 315 grams) 37,500 grains (2 430 grams)
@ 8.0 lb (3.6 kg) @ 12.0 lb (5.4 kg)
22,500 grains (1 450 grams) 43,600 grains (2 825 grams)
@ 12.0 lb (5.4 kg) @ 16.0 lb (7.2 kg)
Freeboard to Media
2
14.75-16.75 in (374.7-425.5 mm) 14.5-16.5 in (368.3-419.1 mm)
Salt Storage Capacity 250 lb (114 kg) 375 lb (170 kg)
Rated Service Flow @ Pressure Drop 7.4 gpm @ 15 psi 7.4 gpm @ 15 psi
(29.6 lpm @ 100 kPa) (31 lpm @ 100 kPa)
Total Hardness, Maximum 75 gpg (1 300 mg/l) 100 gpg (1 700 mg/l)
Total Iron, Maximum 5 ppm (5 mg/l) 5 ppm (5 mg/l)
Hardness to Iron Ratio, Minimum
4
8 gpg Hardness to 1 ppm Iron 8 gpg Hardness to 1 ppm Iron
(140 mg/l Hardness to 1 mg/l Iron) (140 mg/l Hardness to 1 mg/l Iron)
Operating Pressure 20 - 125 psi (140 - 860 kPa) 20 - 125 psi (140 - 860 kPa)
Operating Temperature 33 - 120°F (1 - 50°C) 33 - 120°F (1 - 50°C)
Electrical Requirements 120 Volts AC, 60 Hertz 120 Volts AC, 60 Hertz
Electrical Power Consumption, 3 Watts/25 Watts 3 Watts/25 Watts
Min/Max
Drain Flow, Maximum
5
3.4 gpm (13 lpm) 3.4 gpm (13 lpm)
Recharge Time, Average
6
70 min 70 min
Recharge Water Consumption, 64 gal (242 liters) 110 gal (416 liters)
Average
6
1
Capacities and corresponding salt dosages pertain to low hardness waters. Capacities given are per recharge.
2
Measured from top of media to top of inlet fitting (backwashed and drained).
3
Measured from top of underbedding to top of inlet fitting.
4
Hardness to iron ratio does not apply and total hardness and iron specifications change as follows when
Sofner-Gard
™
Accessory is used.
5
Backwash at 120 psi (830 kPa).
6
10 minute backwash.