144
Curtis 1232E/34E/36E/38E & 1232SE/34SE/36SE Manual, os 30
24 NOVEMBER 2015
Table 6 TROUBLESHOOTING CHART, cont’d
PROGRAMMER LCD DISPLAY
CODE
EFFECT OF FAULT
POSSIBLE CAUSE
SET/CLEAR CONDITIONS
9 — DIAGNOSTICS & TROUBLESHOOTING
92 EM Brake Failed to Set 1. Vehicle movement sensed after the Set: After the EM Brake was commanded
ShutdownEMBrake;
EM Brake has been commanded to set and time has elapsed to allow the
Shutdownrottle. to set. brake to fully engage, vehicle movement
Position Hold is engaged
2. EM Brake will not hold the motor has been sensed.
when Interlock=On. from rotating. Clear: Activate the throttle.
93 Encoder LOS (Limited 1. Limited Operating Strategy (LOS) Set: Encoder Fault (Code 36) or Stall
Operating Strategy) control mode has been activated, as Detect Fault (Code 73) was activated,
Enter LOS control mode.
a result of either an Encoder Fault and Brake or Interlock has been applied
(Code 36) or a Stall Detect Fault to activate LOS control mode, allowing
(Code 73). limited motor control.
2. Motor encoder failure. Clear: Cycle KSI or, if LOS mode was acti-
3. Bad crimps or faulty wiring. vated by the Stall Fault, clear by ensuring
4. Vehicle is stalled. encoder senses proper operation, Motor
RPM = 0, and rottle Command = 0.
94 EMR Rev Timeout 1. Emergency Reverse was activated Set: Emergency Reverse was activated and
ShutdownEMBrake;
and concluded because the EMR ran until the EMR Timeout timer expired.
Shutdownrottle. Timeout timer has expired. Clear: Turn the emergency reverse input
2. e emergency reverse input is O.
stuck On.
98 Illegal Model Number 1. Model_Number variable contains Set: Illegal Model_Number variable; when
ShutdownMotor;
illegal value. KSI cycles, a check is made to conrm
ShutdownMainContactor; 2. Software and hardware do not match. a legal Model_Number, and a fault is
ShutdownEMBrake;
3. Controller defective. issued if one is not found.
Shutdownrottle;
Clear: Download appropriate software
FullBrake.
for your controller model.
99 Parameter Mismatch 1. Dual Motor Enable parameter is set On Set: When the Dual Drive software is
ShutdownMotor;
and Control Mode Select parameter enabled, the controller must be set to
ShutdownMainContactor; not set to 1 (Speed Mode Express) either Speed Mode Express or Speed Mode;
ShutdownEMBrake;
or 2 (Speed Mode). otherwise this fault is set.
Shutdownrottle;
2. Motor Technology and Feedback Motor Techology=0 must be paired
FullBrake.
Type parameters do not match.
with Feedback Type=1, and Motor Tech-
nology=1 must be paired with Feedback
Type=2; otherwise this fault is set.
Clear: Adjust parameters to appropriate
values and cycle KSI.