EasyManua.ls Logo

Curtis 1238E - Position Feedback Input: Sin;Cos Sensor; Sin;Cos Sensor Input Specifications

Curtis 1238E
157 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24
Curtis 1232E/34E/36E/38E & 1232SE/34SE/36SE Manual, os 30
24 NOVEMBER 2015
2 — INSTALLATION & WIRING: I/O Signal Specifications
Position feedback input: sin/cos sensor
Two control lines are internally configured to read a sin/cos sensor. Position
Feedback A (pin 31) provides the sine signal, and Feedback Position B (pin 32)
provides the cosine signal. e device must be set up with one sensor revolution
per mechanical revolution.
SIN/COS SENSOR INPUT SPECIFICATIONS
operating
input max protected esd
signal name pin voltage
impedance freq. voltage tolerance
Position Feedback A 31 0 to 5 V 150 kΩ 500Hz - 5Vto ± 8kV
Position Feedback B 32 for voltages (MaxV + 10 V) (direct strike)
≤5V;
75 kΩ
for voltages
> 5 V
13
24
1
23
35
12
ese signal tolerances must be maintained over the controller’s voltage and
temperature ranges and the vehicles speed range. e sin/cos waveform peaks
must be away from V
dd
and ground by at least 0.5 V. In the example shown in
the timing diagram below, V
dd
= 5 V.
360° mechanical (1 cycle)
V
pp
V
A
V
B
0.5 V
V
dd
Gnd
V
dd
2
V
dd
2
90°
0.5 V

Table of Contents