2 — USING THE 3301T
Curtis Model 3301T Digital Instrumentation – September 2021
Return to TOC
pg. 14
In addition, you can rapidly change parameter values by factors of 10, 100, or 1000 times the
parameter’s step size. For example, suppose that you need to increase a parameter’s value by 1000
step sizes. Instead of incrementing the value 1000 times, you can increase the value by pressing a
few buttons.
Take the following steps to rapidly change the selected parameters value:
1. Press the
F4
button until the screens upper right corner indicates the factor by which to change
the value. e following table lists the indicators:
Indicator Factor
1
Note: x1 is the default, and indicates that the parameter value
will be incremented or decremented by one step size.
10
100
1000
2. Perform one of the following steps:
To increase the value by the specied factor, press the
+
+
button.
To decrease the value by the specied factor, press the
C
-
-
button.
3. If the value needs further adjustment but by a dierent factor, repeat this procedure.