4 — PROGRAMMABLE PARAMETERS
pg. 39
Return to TOC Curtis Model 3301T Digital Instrumentation – September 2021
ODOMETERS MENU
e 3301T provides three odometers. e Odometers parameters reset the odometers.
Note: e parameters on the Odometers menu of the Monitor menu indicate the odometer data.
ODOMETERS MENU
PARAMETER
CAN INDEX
VALUES
RAW VALUES DATA SIZE
ACCESS LEVEL
DEFAULT VALUE DESCRIPTION
Reset Odometer 1
0x646E:00
Off/On
0–1
16-bit Field Intermediate
Off
When On is specied, resets odometer 1 to 0.
Reset Odometer 2
0x646F:00
Off/On
0–1
16-bit Field Intermediate
Off
When On is specied, resets odometer 2 to 0.
Reset Odometer 3
0x6470:00
Off/On
0–1
16-bit Field Intermediate
Off
When On is specied, resets odometer 3 to 0.
SENDERS MENU
e Senders parameters specify the types of data received by the switch 1–4 inputs.
SENDERS MENU
PARAMETER
CAN INDEX
VALUES
RAW VALUES DATA SIZE
ACCESS LEVEL
DEFAULT VALUE DESCRIPTION
Sender 1 Type
0x6300:00
Enumerated
0–3
32-bit Field Intermediate
0
Congures the switch 1 input:
0 = Switch Input.
1 = Resistor Input (reserved).
2 = Voltage Input (reserved).
3 = Frequency Input (reserved).
Sender 2 Type
0x6301:00
Enumerated
0–3
32-bit Field Intermediate
0
Congures the switch 2 input:
0 = Switch Input.
1 = Resistor Input (reserved).
2 = Voltage Input (reserved).
3 = Frequency Input (reserved).
Sender 3 Type
0x6302:00
Enumerated
0–3
32-bit Field Intermediate
3
Congures the switch 3 input:
0 = Switch Input.
1 = Resistor Input (reserved).
2 = Voltage Input (reserved).
3 = HYD Fault Input (pump controller).
Sender 4 Type
0x6303:00
Enumerated
0–3
32-bit Field Intermediate
3
Congures the switch 4 input:
0 = Switch Input.
1 = Resistor Input (reserved).
2 = Voltage Input (reserved).
3 = TRA Fault Input (traction controller).