17. Control procedures chart
◆Application of winding machine
Wind
INV
POTENTIO METER
Dances
U V W
U
V
W
10V
IN2
CC
Costant setting :
Master inverter setting Cd01=1、Cd04=1、
Winding machine setting : Please set CE88~95 to autotuning.
Cd01=1
Cd04=1Cd35=8Cd36=50Cd38=7CD44=1CE54=1
CE55=0.4
CE56=6.6