6. Constant tables
Constant
NO
Name Description
Setting
value
Factory
setting
Change
during
operation
Com.
add.
Page
CE-00
Slip boost gain
(FG only)
To upgrade the speed accuracy when drive to load
Adjust this constant at the following times
1. Increase setting value when speed is lower than
target value
2. Decrease setting value when speed is higher than
target value
0󲕏2.50 0 Yes X P62
CE-01
Slip boost delay
time (FG only)
Slip boost primary delay time is set in ms unit
Adjust this constant at the following times
1. Reduce the setting when slip boost responsive is
slow
2. When speed is not stabilized, increase the setting
0󲕏
10000
500
ms
No X P62
CE-02
Slip boost limit
(FG only)
Set maximum limit value of slip boost
Set motor rated slip is 100%。
0󲕏250
200
%
No X P62
CE-03
Electrical
adjustable speed
Stop restart
attempts
0:
Self-protection setting value
1: (Cd18) frequency minimum limit value is
recovered under stop status
0󲕏1 0 No X P43
CE-04 Password input For factory adjustment only 0󲕏9999 0 No X P94
CE-05
1
st
step speed
setting
Multi-step function control 1
st
step speed setting
0󲕏400.00
HZ
0 Yes 233 P67
CE-06
2
nd
step speed
setting
Multi-step function control 2
nd
step speed setting
0󲕏400.00
HZ
0 Yes 234 P67
CE-07
3
rd
step speed
setting
Multi-step function control 3
rd
step speed setting
0󲕏400.00
HZ
0 Yes 235 P67
CE-08
4
th
step speed
setting
Multi-step function control 4
th
step speed setting
0󲕏400.00
HZ
0 Yes 236 P67
CE-09
5
th
step speed
setting
Multi-step function control 5
th
step speed setting
0󲕏400.00
Hz
0 Yes 237 P67
CE-10
6
th
step speed
setting
Multi-step function control 6
th
step speed setting
0󲕏400.00
HZ
0 Yes 238 P67
CE-11
7
th
step speed
setting
Multi-step function control 7
th
step speed setting
0󲕏400.00
HZ
0 Yes 239 P67
CE-12
8
th
step speed
setting
Multi-step function control 8
th
step speed setting
0󲕏400.00
HZ
0 Yes 240 P67
CE-13
9
th
step speed
setting
Multi-step function control 9
th
step speed setting
0󲕏400.00
HZ
0 Yes 241 P67
CE-14
10
th
step speed
setting
Multi-step function control 10
th
step speed setting
0󲕏400.00
HZ
0 Yes 242 P67
CE-15
11
th
step speed
setting
Multi-step function control 11
th
step speed setting
0󲕏400.00
HZ
0 Yes 243 P67

Table of Contents