13
APPENDIX I
Power Consumption and Thermal Emissions: D-100
No Sig'l = Quiescent, Light = Crest Factor of 7.8(18dB),
Average = Crest Factor of 4.8(14dB), Heavy = Crest Factor of 2.8(9dB)
For details of measurement methods please refer to the Technical Support area of our website.
PRC Settings and Maximum Output: D-100
Mains
(V)
Load
(R)
Current Draw
(A)
Thermal Emissions
(W)
No Sig’l Light Average Heavy No Sig’l Light Average Heavy
240 8
2.1 3.0 4.5 8.3 504 528 566 660
240 4
2.1 3.9 7.0 14.4 504 551 628 816
240 2
2.1 4.5 8.6 19.1 504 564 668 936
120 8
4.2 6.0 9.0 16.6 504 528 566 660
120 4
4.2 7.8 14.0 28.8 504 551 628 816
120 2
4.2 9.0 17.2 38.2 504 564 668 936
Power Reduction Control Setting Per Channel Bridged Pair
Maximum Power into 8 ohms (W)
1400 5300
-2dB PRC
980 3700
-4dB PRC
560 2100
-6dB PRC
310 1175
Maximum Power into 4 ohms (W)
2800 7400
-2dB PRC
1950 5160
-4dB PRC
1110 2940
-6dB PRC
620 1640
Maximum Power into 2 ohms (W)
3700 N/A
-2dB PRC
2580 N/A
-4dB PRC
1470 N/A
-6dB PRC
820 N/A