DES-3028 DES-3028P DES-3028G DES-3052 DES-3052P Layer 2 Fast Ethernet Switch CLI Reference Manual
275
40
MLD SNOOPING COMMANDS
The MLD Snooping commands in the Command Line Interface (CLI) are listed (along with the appropriate parameters) in the
following table.
Command Parameters
config mld_snooping [ vlan <vlan_name 32> | vlanid <vlanid_list>|all] {
node_timeout <sec 1-16711450> | router_timeout <sec 1-
16711450> | done_timer <sec 1-16711450> | state
[enable|disable] | fast_done [enable|disable] }
config mld_snooping
mrouter_ports
[<vlan_name 32>| [add|delete]<portlist>
config mld_snooping
mrouter_ports_forbidden
[<vlan_name 32>] [add|delete]<portlist>
enable mld_snooping
disable mld_snooping
show mld_snooping {vlan <vlan_name 32>| vlanid <vlanid_list>}
show mld_snooping group {vlan <vlan_name 32>| vlanid <vlanid_list>}
show mld_snooping
mrouter_ports
{vlan <vlan_name 32>| vlanid <vlanid_list>} {
[static|dynamic|forbidden]}
Each command is listed, in detail, in the following sections.
config mld_snooping
Purpose Used to configure MLD snooping on the switch.
Syntax
config mld_snooping [ vlan <vlan_name 32>| vlanid
<vlanid_list>| |all] { node_timeout <sec 1-16711450> |
router_timeout <sec 1-16711450> | done_timer <sec 1-16711450>
| state [enable|disable] | fast_done [enable|disable] }
Description The config mld_snooping command configures MLD snooping on the
switch. If the MLD version is configured with a lower version, the
higher version's MLD Report/Leave messages will be ignored.
Parameters
<vlan_name 32> The name of the VLAN for which MLD snooping is
to be configured.
all Specifies that all VLANs will be configured.
node_timeout Specifies the amount of time that must pass before a
link node is considered to not be a listener anymore. The default is
260 seconds.
router_timeout Specifies the maximum amount of time a router will
remain in the switch, and can be a listener of a multicast group
without the switch receiving a node listener report. The default is 260
seconds.
done_timer Specifies the maximum amount of time a group will
remain in the switch after receiving a done message from the group
without receiving a node listener report. The default setting is 2
seconds.
state Allows you to enable or disable the MLD snooping function for