DGS-3000 Series Gigabit Ethernet Switch Hardware Installation Guide
43
Feature
Description
The auto-discovery feature automatically recognizes the
connection of the PD device and immediately provides power.
Automatically disable ports if the port current is over 600mA
while. Other ports will remain active.
Active circuit protection automatically disables the port if there is
a short while other ports remain active.
For 802.3af/at capable devices it will provide the power for the
following classifications below.
Class
Usage
Max Power used by PD
0
Default
0.44 Watts to 12.95 Watts
1
Optional
0.44 Watts to 3.84 Watts
2
Optional
3.84 Watts to 6.49 Watts
3
Optional
6.49 Watts to 12.95 Watts
4
Reserved
12.95 Watts to 25.5 Watts
Follow the PSE pinout standard. For an alternative solution, send
the power over pins 1, 2, 3 and 6 of 8 wires of UTP cables.
For IEEE 802.3af, use category 5e or higher UTP/STP cables.
Category 3 cables can be used if less power is required.
For IEEE 802.3at, use category 5e or higher UTP/STP cables
Both DGS-3000-28LP and DGS-3000-28XMP work with all D-
Link 802.3af and 802.3at capable devices and with all non-
802.3af and non-802.3at capable D-Link Access Points, IP
Cameras and IP Phones.
The total power budget is 193 Watts for DGS-3000-28LP.
The total power budget is 370 Watts for DGS-3000-28XMP.