DWS-3160 Series Gigabit Ethernet Unified Switch Web UI Reference Guide
445
extended IP ACL rule.
IP DSCP – Select one of the DSCP keyword values from the IP DSCP drop-down
menu. When selecting Other, the IP DSCP Value field appears. Enter a value in
the field.
IP Precedence – Enter a value between 0 and 7 in the IP Precedence field.
IP ToS – Enter a value as a hexadecimal number from 00 to FF in the IP ToS Bits
and IP ToS Mask field.
Click the Apply button to accept the changes made.
Click the Cancel button to discard the configuration.
IPv6 Access Control Lists
This window is used to configure IPv6 Access Control Lists.
To view this window, click QoS > Access Control Lists > IPv6 Access Control Lists as shown below:
Figure 4-10 IPv6 Access Control Lists window
The fields that can be configured are described below:
Parameter Description
IPv6 ACL Name
Enter the ID or name of the IPv6 ACL.
Click the Add button to add a new entry based on the information entered.
Click the Rename ACL button to change the name of the specific ACL.
Click the Add / Delete Rules to configure the ACL rules.
Click the Delete ACL to remove the entry from the list.
Enter a page number and click the Go button to navigate to a specific page when multiple pages exist.
After clicking the Rename ACL button, the following page will appear:
Figure 4-11 IPv6 Access Control Lists – Rename window
The fields that can be configured are described below:
Parameter Description
New IPv6 ACL Name
Enter a new name of IPv6 ACL.
Click the Apply button to accept the changes made.
Click the Cancel button to discard the configuration.