NO BAKE/BROIL HEAT:
ERG30
1. Check for incoming voltage to the main relay board at the DBL (Double Line Relay) NO
side to neutral. Should have 120 VAC present. If no voltage check wiring back to the
power terminal block.
If voltage is present go to step 2.
2. After programming the unit into the bake cycle or any cooking cycle “cooling fan must be
running” Check voltage from the com side of the DBL relay to the BA relay (Bake relay)
and the BR (Broil Relay) should have 120 VAC present.
Note: the BA relay and the BR relay are the neutral side to the glow bar igniters. If no
voltage present replace main relay board. If voltage is present go to step 3.
3. If cooling fan is not running check voltage at L2 next to the CLF relay (cooling fan)
to neutral.
Should read 120 VAC. If no voltage check wiring from L2 back to power terminal
block. If voltage is present check wiring to the cooling fan blower, if wiring ok replace
cooling fan assy.