Technical Manual - Page 30
NO BROIL
ERD30, 36, 48
1.
Program unit into the broil cycle.
Take an amp reading at the broiler igniter. You should have 3.1 to 3.3 amps. Or take a voltage
reading at the main relay board. At the main relay board take a voltage check from the BR
(broil relay) to neutral should read 120 volts AC. If no voltage out of the BR relay - replace
relay board. If you have voltage out of the relay board check the HTC (High temp cutout) to
see if the HTC has tripped.
(Remember the broil HTC has the white wire hook to it. You can do this by pushing down
on the reset button located in the center of the HTC. If the HTC won’t reset or is open,
replace HTC. If the HTC is good, go to step 2.
2.
Dual Valve: The HTC (Hi temp cutout) feeds the neutral into the dual valve then the
dual valve feeds the neutral to the broil igniter. If the dual valve is bad then the broil igniter
won’t be energized.