This document is a comprehensive Use & Care Manual for the DAEWOO Portable Type Room Air Conditioner, models DOC-091R and DOC-091RH. It provides essential information for safe operation, installation, and maintenance of the unit, ensuring optimal performance and longevity.
The primary function of this device is to provide room air conditioning, offering various modes to enhance indoor comfort. Depending on the model, it can perform cooling, dehumidifying, fan-only operation, and heating functions. The DOC-091R model is designed for cooling, dehumidifying, and fan operation, while the DOC-091RH model additionally includes a heating feature.
Usage Features:
The air conditioner is operated via an intuitive control panel located on the unit, or through a remote controller for convenience.
- Digital Display: A central digital display provides visual feedback on current settings and operational status.
- Mode Selection: The "MODES BUTTON" allows users to cycle through different operational modes: COOL, DRY, FAN, and HEAT (for DOC-091RH). A green indicator lamp lights up to confirm the selected mode.
- Temperature Setting: The "TEMP SETTING BUTTON" (up "A" and down "V" arrows) enables precise adjustment of the desired room temperature. The cooling operation range is typically between 17°C-32°C (63°F-90°F), while the heating operation range (for DOC-091RH) is 5°C-30°C (41°F-86°F). Dehumidifying operates within 13°C-32°C (55°F-90°F).
- Fan Speed Control: The "FAN SPEED BUTTON" allows users to select from HIGH, MED, or LOW fan speeds, optimizing airflow and noise levels according to preference. In dehumidifying mode, the fan runs at a fixed speed.
- Timer Function: The "TIMER ON/OFF BUTTON" facilitates programming the unit to turn on or off automatically. Users can set a desired start or stop time, adjustable from 0.00 to 24 hours. The digital display shows "ON" or "OFF" to indicate the timer status.
- Water Full Indicator: A "WATER FULL INDICATOR" (red lamp) blinks when the internal water tank is full, signaling the need for drainage.
- Power Button: A simple "POWER BUTTON" allows for turning the unit on or off.
- Infrared Signal Receiver: This component receives signals from the remote controller, enabling wireless operation of the unit.
Installation:
Proper installation is crucial for the air conditioner's efficiency and safety.
- Location: The unit should be placed on a flat, spacious surface, ensuring that air outlets are not obstructed. A minimum clearance of 30cm from walls or other obstacles is recommended. The appliance should not be used in a laundry room.
- Power Supply: The unit requires a 115V~60Hz grounded electrical outlet. It should not be connected to a multiple socket outlet shared with other electrical appliances.
- Exhaust Hose: For cooling mode, the flexible exhaust hose and adjustable window slider kit must be installed. The manual provides instructions for both temporary and permanent duct mounting.
- Temporary Mounting: One end of the duct attaches to the exhaust air outlet of the unit, and the other end connects to adaptor B, which is then placed in a nearby window.
- Permanent Mounting: Similar to temporary, but adaptor A is installed onto a wall using wall plugs and screws, and the duct connects to it. A cap is provided to cover the hole when the duct is not in use.
- Duct Length: The duct can be compressed or extended between 500mm and 2000mm, but it is recommended to keep the length to a minimum for optimal performance. It is important not to over-bend the duct.
- Water Pump Drain Hose: Ensure the water pump drain hose is correctly installed before operation.
Drainage Features:
The unit incorporates a sophisticated drainage system to manage condensed water.
- Water Pump Drainage: When the internal water tank's water level reaches a predetermined point, the water pump activates automatically, draining condensed water outside through the connected drain hose. The maximum delivery lift for the water pump is 3.5m. A rubber blockage should be attached to the back hole to prevent continuous drainage during this operation.
- Continuous Drainage: For extended periods of non-use, the rubber blockage can be removed from the back hole, and a continuous drain hose can be attached to the drain hose connector. This allows all water in the tank to drain out, and the water pump will not be activated in this mode.
- Drain Tank Safety Feature: The unit is equipped with two full-safe switch mechanisms. One controls the water pump drainage, and the other monitors the water level. If the water level reaches a predetermined maximum, the "P1" code will appear on the digital display, and the "WATER FULL INDICATOR" will illuminate. In this event, the unit should be moved outside, the rubber blockage removed from the back drainage hole, and the water drained manually. The unit will resume operation once the water is drained.
Maintenance Features:
Regular maintenance is essential for the air conditioner's efficiency and to prevent issues.
- Safety Precautions: Always unplug the unit before cleaning. Do not use gasoline, thinner, or other chemicals. Avoid washing the unit directly with a tap or hose to prevent electrical hazards. If the power cord is damaged, it must be repaired by the manufacturer or an authorized service agency.
- Air Filter Cleaning: The air filter should be cleaned at least once every two weeks to maintain optimal fan operation and prevent dust buildup.
- Removal: Pull out the filter cover and then remove the air filter from the cover.
- Cleaning: Immerse the air filter gently in warm water (about 40°C/104°F) with a neutral detergent. Rinse thoroughly and dry it in a shady place.
- Mounting: Attach the clean, dry air filter to the filter cover using the attachment hooks and then put the filter cover back onto the unit.
- Unit Enclosure Cleaning: Use a lint-free cloth dampened with neutral detergent to clean the unit's exterior. Finish by wiping with a dry, clean cloth.
Troubleshooting:
The manual includes a troubleshooting guide to address common issues:
- Unit Not Starting: If the unit doesn't start when the power button is pressed, check if the "WATER FULL INDICATOR" is blinking, indicating a full water tank. The solution is to dump the water.
- Insufficient Cooling/Heating:
- If the room temperature is higher than the set temperature (heating mode) or lower than the set temperature (cooling mode), reset the temperature.
- Ensure all windows and doors are closed.
- Remove any heat sources inside the room.
- Verify that the exhaust air duct is properly connected and not blocked.
- If the temperature setting is too high (for cooling), decrease it.
- Check if the air filter is blocked by dust and clean it if necessary.
- Power Shut Off in Heating Mode: This indicates the automatic over-heat protection function has activated, typically when the air outlet temperature exceeds 70°C (158°F). The unit will stop and should be switched on again after it has cooled down.
- Noisy or Vibrating Unit: Ensure the unit is placed on a flat, level ground.
- Gurgling Sound: This is normal and comes from the flowing of refrigerant inside the air conditioner.
Safety Rules:
Several safety rules are emphasized to prevent accidents and ensure proper operation:
- Do not connect the unit to a damaged AC socket.
- Avoid using the unit near fire sources, areas prone to oil or water splashes, direct sunlight, baths, showers, swimming pools, or in a greenhouse.
- Never insert fingers or foreign objects into the air outlet, especially warning children about this danger.
- Always store the unit upright to maintain the compressor in proper condition.
- Unplug the unit before cleaning.
- The heater (if applicable) must not be located immediately below a socket outlet.
- Avoid covering the appliance to prevent overheating.
- If the supply cord is damaged, it must be replaced by a repair shop appointed by the manufacturer using special purpose tools.
- The air conditioner should only be connected to a supply with a system impedance no more than 0.4582 ohm. Consult the supply authority if necessary.
This manual serves as a complete guide for users to effectively operate and maintain their DAEWOO portable room air conditioner, ensuring comfort and safety.