EasyManua.ls Logo

Daewoo G424E - Page 58

Daewoo G424E
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
G420E/G424E Tier LP Engine Advanced Diagnostics 57
Table a. MI-04 Diagnostic Fault Codes (Flash Codes)
DFC Probable Fault Action Corrective Action, First Check
65 Pedal2SensorInputLo
APP2 sensor failure or shorted circuit
MIN power Limit Check Acceleration Pedal connector
z Cycle the pedal several times
and check APP2 signal at SECM
PIN 2
66 Pedal2SensorInputHi
APP2 signal disconnected, open
circuit or sensor malfunction
(Expected faults when APP connector
is unplugged
CODES: 61 & 66)
MIN power Limit Check Acceleration Pedal connector
z Check APP2 signal at SECM
PIN 2
67 Pedal2SensorRangeLo
APP2 potentiometer malfunction.
Improper APP2 reading may be due
to dirt or oxidation on the sensor
traces.
Stored Fault Code
(MIL Only)
Check Acceleration Pedal connector
z Cycle the pedal several times
and check APP2 signal at SECM
PIN 2
68 Pedal2SensorRangeHi
APP2 potentiometer malfunction.
Improper APP2 reading may be due
to dirt or oxidation on the sensor
traces.
Stored Fault Code
(MIL Only)
Check Acceleration Pedal connector
z Cycle the pedal several times
and check APP2 signal at SECM
PIN 2
69 Pedal1ToPedal2Difference
Measured APP2 pedal position signal
is different than APP1 signal
MIN power Limit Check Acceleration Pedal connector
z Cycle the pedal several times
and check APP1 signal at SECM
PIN 15
z Check APP2 signal at SECM
PIN 2
71 AFRTrimValveOutput
FTV modulation driver signal fault
Stored Fault Code
(MIL, Disable Adaptive
learns)
Check FTV for an open wire or FTV
connector being disconnected
FTV PIN A (SIGNAL) TO PIN B
(PWR)
Check FTV for an open coil by
disconnecting the FTV connector and
measuring the resistance (~26 +/-
2)
FTV PIN A (SIGNAL) TO PIN B
(PWR)

Table of Contents