5.10.7 Thermal Alarm
Background Information
After receiving the alarm signal from the connected thermal devices, the system can recognize the
alarm type, and then trigger the corresponding alarm actions.
The system supports heat alarm, temperature (temperature dierence) and cold/hot alarm.
●
Heat alarm: The system generates an alarm once it detects there is a re.
●
Temperature (temperature dierence): The system triggers an alarm once the temperature
dierence between two positions is higher or below the specied threshold.
●
Cold/hot alarm: The system triggers an alarm once the detected position temperature is higher
or below the specied threshold.
●
Make sure that the connected camera supports temperature monitoring function.
●
This function is available on select models.
●
The thermal detection functions might vary depending on the connected camera. This section
uses heat alarm as an example.
Procedure
Step 1 Select Main Menu > ALARM > Thermal Alarm.
Figure 5-214 Thermal alarm
Step 2 Select a channel and set alarm type to heat alarm, and then enable the function.
Step 3 Select re mode. The system supports preset mode and zone excluded mode.
●
Preset mode: Select a preset and then enable the function. The system generates an
alarm once it detects there is a re.
●
Zone excluded mode: The system lters the specied high temperature zone. The
system generates an alarm once the rest zone has re.