Removal of Sound Blankets Si12-891
14 Removal Procedure
4. Removal of Sound Blankets
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure Points
1. Remove the right side
panel.
Preparation
Remove the panels
according to the “Removal of
Outer Panels”.
Remove the electrical box
according to the “Removal of
Electrical Box”.
1
Remove the 6 screws
and remove the right
side panel.
2. Remove the partition
plate.
When reassembling, fit the
lower hooks into the bottom
frame.
1
Remove the 2 screws.
2
The partition plate has
2 hooks on the lower
side. Lift and pull the
partition plate and
remove it.
(R12567)
Right side
panel
(R7611)
Partition plate
(R7612)
Remove the screw to
remove the reactor.