Si12-891 Removal of Four Way Valve / Outdoor Electronic Expansion Valves
Removal Procedure 23
4
Heat up the brazed
parts.
Pull the pipe with pliers
and disconnect.
Note:
Do not use a metal saw for
cutting pipes by all means
because the sawdust comes
into the circuit.
When withdrawing the pipes,
be careful not to pinch them
firmly with pliers. The pipes
may get deformed.
Provide a protective sheet or
a steel plate so that the
brazing flame cannot
influence peripheries.
Step
Procedure Points
(R7651)