5 Electrical installation
Installation manual
12
ETVH/X16S18+23DA6V+9W(G)
Daikin Altherma 3 H HT F
4P586454-1 – 2019.07
Backup
heater type
Backup
heater
capacity
Power
supply
Maximum
running
current
Z
max
*6V 2kW 1N~230V
(a)
9A
4kW 1N~230V
(a)
17A
(b)(c)
0.22Ω
6kW 1N~230V
(a)
26A
(b)(c)
0.22Ω
2kW 3~230V
(d)
5A
4kW 3~230V
(d)
10A
6kW 3~230V
(d)
15A
*9W 3kW 3N~400V 4A
6kW 3N~400V 9A
9kW 3N~400V 13A
(a)
6V
(b)
Electrical equipment complying with EN/IEC 61000-3-12
(European/International Technical Standard setting the
limits for harmonic currents produced by equipment
connected to public low-voltage systems with input
current >16A and ≤75A per phase).
(c)
This equipment complies with EN/IEC61000‑3‑11
(European/International Technical Standard setting the
limits for voltage changes, voltage fluctuations and
flicker in public low-voltage supply systems for
equipment with rated current ≤75A) provided that the
system impedance Z
sys
is less than or equal to Z
max
at
the interface point between the user's supply and the
public system. It is the responsibility of the installer or
user of the equipment to ensure, by consultation with the
distribution network operator if necessary, that the
equipment is connected only to a supply with a system
impedance Z
sys
less than or equal to Z
max
.
(d)
6T1
Connect the backup heater power supply as follows:
X6M
F1B
Q1DI
a
b
a Factory-mounted cable connected to the backup heater
contactor inside the switch box (K5M)
b Field wiring (see table below)
Model (power
supply)
Connections to backup heater power
supply
*6V (6V: 1N~230V)
1N~, 50 Hz
230 V AC
SWB
4
3
6
5
2
1
K5M
14
13
Q1DI
1
2
3
4
5
6
7
8
F1B
II I I
NL
X6M
BRN
GRY
BLU1
BLU2
Model (power
supply)
Connections to backup heater power
supply
*6V (6T1: 3~230V)
SWB
3~, 50 Hz
230 V AC
4
3
6
5
2
1
K5M
14
13
1
2
3
4
5
6
7
8
F1B
II I I
Q1DI
L1 L2 L3
X6M
BRN
GRY
BLU1
BLU2
*9W (3N~400V)
3N~, 50 Hz
400 V AC
SWB
Q1DI
L1 L2 L3 N
1
2
3
4
5
6
7
8
F1B
II I I
X6M
2
1
K5M
4
3
6
5
14
13
BRN
GRY
BLK
BLU
F1B Overcurrent fuse (field supply). Recommended fuse:
4‑pole; 20A; curve 400V; tripping class C.
K5M Safety contactor (in the lower switch box)
Q1DI Earth leakage circuit breaker (field supply)
SWB Switch box
X6M Terminal (field supply)
NOTICE
Do NOT cut or remove the backup heater power supply
cable.
5.2.3 To connect the shut-off valve
INFORMATION
Shut-off valve usage example. In case of one LWT zone,
and a combination of underfloor heating and heat pump
convectors, install a shut-off valve before the underfloor
heating to prevent condensation on the floor during cooling
operation. For more information, see the installer reference
guide.
Wires: 2×0.75mm²
Maximum running current: 100mA
230VAC supplied by PCB
[2.D] Shut off valve