9 | Electrical installation
Installer reference guide
105
EPRA14~18D + ETVH/X16S18+23E
Daikin Altherma 3 H HT F
4P644737-1A – 2022.03
L N PE
1 2
4 (Optional) Power saving function: If you want to use the power saving
function:
Disconnect X804A from X805A.
Connect X804A to X806A.
X806A
X804A
X805A
INFORMATION
Power saving function. The power saving function is only applicable for V3 models.
For more information about the power saving function ([9.F] or overview field setting
[E‑08]), see "Power saving function"[4214].
In case of W1 models
1 Power supply cable:
Route the cable through the frame.
Connect the wires to the terminal block.
Fix the cable with a cable tie.
Wires: 3N+GND
Maximum running current: Refer to name plate on unit.