6 | Application guidelines
Installer reference guide
57
EPRA14~18D + ETVH/X16S18+23E
Daikin Altherma 3 H HT F
4P644737-1A – 2022.03
# Power consumption control
1 "6.6.1Permanent power limitation"[457]
▪ Allows you to limit the power consumption of the entire heat pump
system (sum of indoor unit and backup heater) with one permanent
setting.
▪ Limitation of power in kW or current in A.
2 "6.6.2Power limitation activated by digital inputs"[458]
▪ Allows you to limit the power consumption of the entire heat pump
system (sum of indoor unit and backup heater) via 4 digital inputs.
▪ Limitation of power in kW or current in A.
3 "6.6.4BBR16 power limitation"[460]
▪ Restriction: Only available in Swedish language.
▪ Allows you to comply with BBR16 regulations (Swedish energy
regulations).
▪ Limitation of power in kW.
▪ Can be combined with the other kW power consumption controls. If you
do so, the unit uses the most restrictive control.
NOTICE
It is possible to install a field fuse with lower than recommended rating over the heat
pump. For this you must modify field setting [2‑0E] according to the maximum
allowed current over the heat pump.
Note that field setting [2‑0E] overrules all power consumption control settings.
Power limiting the heat pump will reduce performance.
NOTICE
Set a minimum power consumption of ±3.6kW to guarantee:
▪ Defrost operation. Otherwise, if defrosting is interrupted several times, the heat
exchanger will freeze up.
▪ Space heating and DHW production by allowing the backup heater step1.
▪ Anti-legionella operation.
6.6.1 Permanent power limitation
Permanent power limitation is useful to assure a maximum power or current input
of the system. In some countries, legislation limits the maximum power
consumption for space heating and DHW production.
P
i
Power input
t Time
DI Digital input (power limitation level)
a Power limitation active
b Actual power input