5/10
Breadcrumb Field code Setting name Range, step
Default value
Date Value
Installer setting at variance with
default value
Field settings table
9.1 [0-05] R/W [9-07]~[9-08]°C, step: 1°C
12°C
9.1 [0-06] R/W 25~43°C, step: 1°C
35°C
9.1 [0-07] R/W 10~25°C, step: 1°C
20°C
└─ Tank
9.1 [6-0D] R/W 0: Reheat only
1: Reheat + sched.
2: Scheduled onl
y
9.1 [6-0A] R/W 30~[6-0E]°C, step: 1°C
60°C
9.1 [6-0B] R/W 30~min(50, [6-0E])°C, step: 1°C
45°C
9.1 [6-0C] R/W 30~min(50, [6-0E])°C, step: 1°C
45°C
└─ Domestic hot water
9.2.1 [E-05]
[E-06]
[E-07]
R/W
No DHW (*3)
EKHW (*3)
Integrated (*4)
EKHWP
(
*3
)
9.2.2 [D-02] R/W
0: No
1: Secondary rtrn
2: Disinf. Shunt
9.2.4 [D-07] R/W
0: No
1: Yes
└─ Back up heater
9.3.1 [E-03] R/O
3: 6V (*1)
4: 9W
(
*2
)
9.3.2 [5-0D] R/W (*1)
R/O (*2)
0: 230V, 1~ (*1)
1: 230V, 3~ (*1)
2: 400V
,
3~
(
*2
)
9.3.3 [4-0A] R/W
1: 1/1+2 (*1) (*2)
2: 1/2
3: 1/2 + 1/1+2 in emer
g
enc
y
9.3.4 [6-03] R/W 0~10kW, step: 0,2kW
2kW (*1)
3kW
(
*2
)
9.3.5 [6-04] R/W 0~10kW, step: 0,2kW
4kW (*1)
6kW
(
*2
)
9.3.6 [5-00] R/W 0: Allowed
1: Not allowed
9.3.7 [5-01] R/W -15~35°C, step: 1°C
0°C
9.3.8 [4-00] R/W 0: Disabled
1: Enabled
2: Onl
y
DHW
└─ Booster heater
9.4.1 [6-02] R/W 0~10kW, step: 0,2kW
3kW (*3)
0kW
(
*4
)
9.4.3 [8-03] R/W 20~95 min, step: 5 min
50 min
9.4.4 [4-03] R/W 0: Restricted
1: Allowed
2: Overlap
3: Compressor off
4: Le
g
ionella onl
y
Installer settings
9.5 [4-06] R/W
0: Manual
1: Automatic
└─ Balancing
9.6.1 [5-02] R/W
0: Disabled
1: Enabled
9.6.2 [5-03] R/W -15~35°C, step: 1°C
0°C
9.6.3 [5-04] R/W 0~20°C, step: 1°C
10°C
9.6.4 [8-02] R/W 0~10 hour, step: 0,5 hour
0,5 hour [E-07]=1
3 hour
[
E-07
]
≠1
9.6.5 [8-00] R/O
0~20 min, step 1 min
1 min
9.6.6 [8-01] R/W 5~95 min, step: 5 min
30 min
9.6.7 [8-04] R/W 0~95 min, step: 5 min
95 min
Installer settings
9.7 [4-04] R/O
0: Intermittent
└─ Benefit kWh power supply
9.8.1 [D-01] R/W
0: No
1: Active open
2: Active closed
3: Safet
y
thermostat
9.8.2 [D-00] R/W
0: None
1: BSH only
2: BUH only
3: All heaters
9.8.3 [D-05] R/W 0: Forced off
1: As normal
└─ Power consumption control
9.9.1 [4-08] R/W
0: No limitation
1: Continuous
2: Di
g
ital in
p
uts
9.9.2 [4-09] R/W 0: Current
1: Power
9.9.3 [5-05] R/W 0~50 A, step: 1 A
50
A
9.9.4 [5-05] R/W 0~50 A, step: 1 A
50
A
9.9.5 [5-06] R/W 0~50 A, step: 1 A
50
A
Leaving water value for low ambient temp. for LWT add zone cooling WD curve.
High ambient temp. for LWT add zone cooling WD curve.
Low ambient temp. for LWT add zone cooling WD curve.
Heat up mode
Comfort setpoint
Eco setpoint
Reheat setpoint
Domestic hot water
DHW pump
Solar
BUH type
Voltage
Configuration
Capacity step 1
Additional capacity step 2
Equilibrium
Equilibrium temperature
Operation
Capacity
BSH eco timer
Operation
Emergency
Space heating priority
Priority temperature
Offset BSH setpoint
Anti-recycle timer
Minimum running timer
Maximum running timer
Additional timer
Water pipe freeze prevention
Benefit kWh power supply
Allow heater
Allow pump
Power consumption control
Type
Limit
Limit 1
Limit 2
(*1) *6V_(*2) *9W_
(*3) *AB*_(*4) EAV*_
(*5) *X*_(*6) *H*_
(*7) EAV*18*_(*8) EAV*23*
(#) Setting is not applicable for this unit. 4P556072-1 - 2018.12