Indoor Unit SiBE04-809
160 Removal Procedure
4. Remove the heat
exchanger.
1
Widen the auxiliary
piping to the extent of
10°~20°.
2
Loosen the 2 screws on
the left.
3
Push the fixing hook on
the right side and lift the
heat exchanger.
Caution
When removing or
reinstalling heat exchanger,
be sure to wear protective
gloves or wrap the heat
exchanger with cloths. (Fins
can cut fingers.)
4
Pull the heat exchanger
to the front side and
then lift and remove it.