SiBE04-809 Control Specification
Function and Control 39
Frequency
Compressor
Four way valve
Fan
Electronic expansion
valve opening
ON
OFF
ON
OFF
ON
OFF
0Hz
5sec.
350pulse 450pulse450pulse
Initial opening
PI control
5sec.
50sec.50sec. 660sec.
60sec.
76Hz
86Hz
30Hz
(R8329)
60sec.
Outdoor temp. < 0˚C
Outdoor temp. 0˚C