Si211309E Procedure to Remove Fan Motor
Removal Procedure 7
6. Procedure to Remove Fan Motor
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure Points
Remove side panels and
other external casing, and
electrical parts box according
to their removal procedures.
Use 2.5 mm hexagon nut driver.
1
Loosen the hexagon set
screw fastening the fan
rotor and fan motor.
2
Remove the fan motor
fastener. (3 screws)
3
Remove the fan motor.
Hexagon nut driver
Fan motor fastener
Fan motor cover
Fan motor retainer
Fan motor