414
FTX-N/U, FVXS-N, FDMQ-R Series EDUS091558E
3P124623-1E
19
error codes (in outline font) do not display “maintenance” and the system will run, but please check the content
of the display and contact your dealer.
L6 Outdoor unit · Ground circuit for compressor motor, short circuit
L8
Outdoor unit · Compressor overload, compressor motor wire
disconnection
L9 Outdoor unit · Compressor lock
LA Outdoor unit · Power unit error
LC
Outdoor unit · Transmission error between inverter and outdoor
control unit
or
M1 Central controller: PC board fault
or
M8 Transmission error between central controllers
or
MA Central controller: Incorrect combination
or
MC Central controller: Address setting fault
P0
Insufficient gas (thermal storage)
P1 Outdoor unit · Power voltage imbalance, phase loss
P4 Outdoor unit · Power unit temperature sensor error
U0
Pressure drop due to insufficient refrigerant, electric expansion
valve fault, etc.
U1 Reversed or lost phase
U2 Power voltage error, momentary electrical stoppage
U4
Transmission error between indoor unit/BEV unit and outdoor/BS
unit, Transmission error between outdoor unit and BS unit
U5
Transmission error between remote controller and indoor
control unit
U5 Remote controller board fault or remote controller setting fault
U6 Transmission error between indoor units
U7
Transmission error between outdoor units
Transmission error between outdoor unit and ice thermal
storage unit
U7
Transmission error between outdoor units
(cooling/heating batch, low-noise operation)
U8
Transmission error between master remote controller and slave
remote controller (slave remote controller error)
Incorrect combination of indoor unit and remote controller within
a single system (model)
U9
Transmission error between indoor unit/BEV unit and outdoor
unit within a single system
Transmission error between BS unit and indoor unit/BEV unit and
outdoor unit within a single system
UA
Incorrect combination of indoor, BS, and outdoor units within a
single system (model, number of units, etc.)
Incorrect combination of indoor unit and remote controller
(remote controller in question) BS unit connection position fault
UC
Central control group numbers overlap
UE Transmission error between indoor unit and central controller
UF
Unset system, incorrect settings between BEV unit and
indoor unit
UH System fault

Table of Contents

Other manuals for Daikin FDMQ-R Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin FDMQ-R Series and is the answer not in the manual?

Daikin FDMQ-R Series Specifications

General IconGeneral
BrandDaikin
ModelFDMQ-R Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals