EasyManua.ls Logo

Daikin FDMQ-R Series - 4 Dimensions; Indoor Unit

Daikin FDMQ-R Series
484 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14
FTX-N/U, FVXS-N, FDMQ-R Series EDUS091558E
REAR
RIGHTLEFT
( )
BOTTOM
FLAPS
13/16 (20mm)
UP/DOWN (AUTOMATIC)
COOLING, DRY FANHEATING
10°
15°
20°
30°
25°
35°
80°
80°
70°
55°
65°
7-1/16 (180mm)
65°
RIGHT/LEFT (MANUAL)
45°
45°
(ARC480A8)
39 (990mm)
THE MARK () SHOWS PIPING DIRECTION
FRONT GRILLE FIXING SCREWS
(INSIDE)
SIGNAL TRANSMITTER
1-7/8 (48mm)
WIRELESS REMOTE CONTROLLER
BLADE ANGLES
SIGNAL RECEIVER
OPERATION LAMP
TIMER LAMP
INDOOR UNIT ON/OFF SWITCH
ROOM TEMP. THERMISTOR
(INSIDE)
DRAIN HOSE
(CONNECTING PART
I.D. φ9/16 (φ14mm)
O.D. φ5/8 (φ16mm)
GAS PIPE φ1/2 (φ12.7mm) CuT
UP AND DOWN WIND DIRECTION
CONTROL BLADE MOVABLE RANGE
1/2 (12mm) 11-5/8 (295mm)
TERMINAL BLOCK
WITH GROUND
TERMINAL
(INSIDE)
GENERAL RATING
NAME PLATE
10-7/16 (265mm)
10-3/8 (263mm)
INCLUDING
MOUNTING PLATE
1-15/16 (50mm) MIN
(SPACE FOR
MAINTENANCE)
AIRFLOW (INDOOR)
REQUIRED SPACE
1-15/16 (50mm) MIN
(SPACE FOR
MAINTENANCE)
1-3/16 (30mm) MIN
(SPACE FOR
PERFORMANCE)
ABOUT 15-3/4 (400mm)
ABOUT 17-5/16 (440mm)
ABOUT 18-1/8 (460mm)
LIQUID PIPE φ1/4 (φ6.4mm) CuT
DRAIN HOSE
GAS PIPE
LIQUID PIPE
ABOUT 14-3/16 (360mm)
ABOUT 14-3/8 (365mm)
ABOUT 17-3/4 (450mm)
39 (990mm)
29-3/8 (746mm)
5 (126.5mm)
9/16 (14.6mm)
1-3/4 (44.5mm)
5/16 (7.9mm)
11-5/8 (295mm)
1-3/4 (44.5mm)
1-7/8 (48mm)
WALL HOLE FOR EMBEDDED PIPING
φ3-1/8 (φ80mm) HOLE
STANDARD LOCATIONS OF WALL HOLES
2-3/8 (60mm)
WALL HOLE
φ3-1/8 (φ80mm) HOLE
MODEL NAME PLATE
C: 3D091779A
FTX15NMVJU
5/16
(
7.9 mm
)
45°
45°
8-7/8
(
225 mm
)
1-1/16
(
27 mm
)
5-3/16
(
132 mm
)
ABOUT 14-9/16
(
370 mm
)
11-1/4
(
285 mm
)
1-7/8
(
48 mm
)
8-3/4
(
223 mm
)
30-5/16
(
770 mm
)
ABOUT 13
(
330 mm
)
13/16
(
20 mm
)
4-9/16
(
116.5 mm
)
9/16
(
14.6 mm
)
1-7/8
(
48 mm
)
ABOUT 15-3/8
(
390 mm
)
11-1/4
(
285 mm
)
30-5/16
(
770 mm
)
7-1/16
(
180 mm
)
21-1/8
(
536.6 mm
)
1-15/16
(
50 mm
)
MIN
1-3/16
(
30 mm
)
MIN
1-15/16
(
50 mm
)
MIN
1-3/4
(
44.5 mm
)
1-7/8
(
48 mm
)
1-3/4
(
44.5 mm
)
STANDARD LOCATIONS OF WALL HOLES
BOTTOM
65°
DRAIN HOSE
SIGNAL RECEIVER
AIR FLOW
(
INDOOR
)
REQUIRED SPACE
BLADE ANGLE
UP/DOWN
(
AUTOMATIC
)
FLAPS
INDOOR UNIT ON/OFF SWITCH
RIGHT
COOLING
LEFT
DRY
OPERATION LAMP
50°
LIQUID PIPE
REAR
50°
THE MARK
()
SHOWS PIPING DIRECTION
HEATING
SIGNAL TRANSMITTER
TIMER LAMP
FAN
15°
65°
GAS PIPE
FRONT PANEL FIXING SCREWS
(
INSIDE
)
INCLUDING
MOUNTING PLATE
GENERAL RATING
NAME PLATE
TERMINAL BLOCK
WITH GROUND
TERMINAL
(
INSIDE
)
UP AND DOWN WIND DIRECTION
CONTROL BLADE MOVABLE RANGE
ROOM TEMP. THERMISTOR
(
INSIDE
)
MODEL NAME
PLATE
WIRELESS REMOTE CONTROLLER
(
ARC480A8
)
RIGHT/LEFT
(
MANUAL
)
(
SPACE FOR
MAINTENANCE
)
(
SPACE FOR
MAINTENANCE
)
(
SPACE FOR
PERFORMANCE
)
GAS PIPE
φ
3/8
(φ
9.5 mm
)
CuT
(
THE LENGTH OF PIPE OUTSIDE
THE UNIT: ABOUT 14-3/16
(
360 mm
))
LIQUID PIPE
φ
1/4
(φ
6.4 mm
)
CuT
(
THE LENGTH OF PIPE OUTSIDE
THE UNIT: ABOUT 16-1/8
(
410 mm
))
DRAIN HOSE
(
CONNECTING PART
I.D.
φ
9/16
(φ
14 mm
)
O.D.
φ
5/8
(φ
16 mm
)
(
THE HOSE LENGTH OF OUTSIDE
THE UNIT IS ABOUT 18-1/2
(
470 mm
))
WALL HOLE FOR EMBEDDED PIPING
φ
2-9/16
(φ
65 mm
)
HOLE
WALL HOLE
φ
2-9/16
(φ
65 mm
)
HOLE
C: 3D091702
FTX09/12NMVJU
4.1 Indoor Unit
4. Dimensions

Table of Contents

Other manuals for Daikin FDMQ-R Series

Related product manuals