FTX-N/U, FVXS-N, FDMQ-R Series EDUS091558E
447
3P124623-5C
11
Is it possible to
set times which
straddle days?
Yes, it is possible.
Example:
Start operation at
5:00 a.m. on Sunday
Stop operation at
6:00 p.m. on Monday
The unit does not
turn on even
though the set
“ on ” time has
come.
(When using the
schedule timer
alone)
The following causes
are possible.
1. Are the “ on ” time
and the “ off ” time set
to the same time?
The unit does not
turn on even
though the set
“ on ” time has
come.
(When using the
unit with a central
remote controller)
The following causes
are possible. Check
each one.
1. Was the timer num-
ber set with the cen-
tral remote
controller?
Was an incorrect
timer number set?
2. Is another timer no.
set with the central
remote controller set
for “ off ” at the same
time?
3.
Is the operation code
set to “ remote control
permission timer
using the central
remote controller or
the on/off controller?
The unit oper-
ates even though
that day is set as
a holiday.
(When using the
unit with a central
remote controller)
The following causes
are possible.
1. Is another timer num-
ber set with the cen-
tral remote controller
set for “ on ” at the
same time?
(If two timer numbers
are set, make sure
that the settings for
holidays and working
days do not overlap
between the different
timer numbers.)
The TIME NO. is
not displayed.
The following causes
are possible.
1. The TIME NO. is not
displayed when
using the schedu
le
timer alone.
(It can be set if using
the central remote
controller at the
same time.)
The display
remains
even though I
push the
HOUR/MINUTE
BUTTON in the
timer program
settings.
The following causes
are possible.
1. Is the day set to a
holiday?
I cannot set
“ central manage-
ment priority ” or
“ after-push prior-
ity ” with the
schedule timer.
The following causes
are possible.
1. Is a central remote
controller or on/off
controller also
installed?
∗∗
The priority order of
the operation codes
depends on the
central devices
which are installed.
The below operation
codes are set.
Schedule timer
Central remote
controller is used
as well
Operation code of
the central remote
controller
Schedule timer
On/off controller is
used as well
Operation code of
the on/off control-
ler
Schedule timer
Central remote
controller
On/off controller is
used as well
Operation code of
the central remote
controller

Table of Contents

Other manuals for Daikin FDMQ-R Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin FDMQ-R Series and is the answer not in the manual?

Daikin FDMQ-R Series Specifications

General IconGeneral
BrandDaikin
ModelFDMQ-R Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals