SiENBE05-722_A Outdoor Unit - RK(X)S25/35G2V1B9
Removal Procedure 193
10
Disconnect the
connectors for the
magnetic relay [S50]
and for the forced
operation button PCB
[S100].
11
Disconnect the
connector for the filter
PCB [HL3] [HN3].
12
Release the harnesses
from the hook.
13
Release the harness for
the outdoor
temperature thermistor.
Step
Procedure Points
(R11862)
[S100]
[S50]
[HL3]
[HN3]
(R11863)
(R11864)
(R11865)
SiENBE05-722_A.pdf 202 24/02/2011 14:06:16