Outdoor Unit - RK(X)S25/35G2V1B9 SiENBE05-722_A
194 Removal Procedure
14
Remove the 6 screws.
15
Unfasten the 4 hooks
and remove the main
PCB.
Refer to page 20 for detail.
[S10] [HL3] [HN3]: filter PCB
[S20]: electronic expansion
valve coil
[S40]: overload protector
[S50]: magnetic relay
[S70]: fan motor
[S80]: four way valve coil
[S90]: thermistors
[S100]: forced operation button
PCB
Step
Procedure Points
(R11866)
(R11867)
(R11868)
[HL3]
[S50] [S100]
[S90] [S10]
[HN3]
[HL3]
[S80]
[S20]
[S40]
[S70]