Piping Diagrams SiENBE04-512A
228 Appendix
ARXS20/25C2VMB
ARXS35C2VMB
M
9.5CuT
7.0CuT
7.0CuT
OUTDOOR UNIT
HEAT EXCHANGER
7.0CuT 6.4CuT 6.4CuT
9.5CuT
MUFFLER
PROPELLER FAN
7.9CuT
9.5CuT
9.5CuT
7.9CuT
COMPRESSOR
ACCUMULATOR
9.5CuT
MUFFLER
9.5CuT
FIELD PIPING
FIELD PIPING
(
6.4CuT
)
(
9.5CuT
)
6.4CuT
REFRIGERANT FLOW
HEATING
COOLING
3D043688C
OUTDOOR TEMPERATURE
THERMISTOR
HEAT EXCHANGER
THERMISTOR
MUFFLER
WITH
FILTER
MUFFLER
WITH
FILTER
LIQUID STOP
VALVE
GAS STOP
VALVE
DISCHARGE PIPE
THERMISTOR
FOUR WAY
VALVE
NORMALLY : OFF
MOTOR OPERATED
VALVE
9.5CuT
9.5CuT
7.0CuT
7.0CuT
OUTDOOR UNIT
MUFFLER
PROPELLER FAN
HEAT EXCHANGER
7.9CuT7.9CuT
M
COMPRESSOR
9.5CuT
4.8CuT
4.8CuT
9.5CuT
ACCUMULATOR
6.4CuT
9.5CuT
6.4CuT
FILTER
MUFFLER
9.5CuT
6.4CuT
FIELD PIPING
FIELD PIPING
(
6.4CuT
)
(
9.5CuT
)
REFRIGERANT FLOW
COOLING
HEATING
3D043689D
OUTDOOR TEMPERATURE
THERMISTOR
HEAT EXCHANGER
THERMISTOR
MUFFLER
WITH
FILTER
MUFFLER
WITH
FILTER
LIQUID STOP
VALVE
GAS STOP
VALVE
DISCHARGE PIPE
THERMISTOR
FOUR WAY
VALVE
NORMALLY : OFF
MOTOR OPERATED
VALVE
SiENBE04-512A.book Page 228 Friday, October 5, 2007 1:49 PM

Table of Contents

Related product manuals