Printed Circuit Board Connector Wiring Diagram SiENBE04-512A
32 Printed Circuit Board Connector Wiring Diagram
1.2 Outdoor Unit / ARK(X)S-C
Connectors
Note: Other designations
1) S10 Connector for filter PCB
2) S11 Connector for control PCB
3) S20 Connector for electronic expansion valve coil
4) S30 Connector for compressor motor
5) S40 Connector for overload protector
6) S70 Connector for fan motor
7) S80 Connector for four way valve coil
8) S90 Connector for thermistors
(outdoor air, heat exchanger, discharge pipe)
9) HC3, HC4, HL3, HN3 Connector for filter PCB
1) FU1, FU2 Fuse (3.15A)
2) FU3 Fuse (20A)
3) LED A Service monitor LED
4) V1, V2, V3 Varistor
5) J8 Facility setting jumper
Refer to page 63 for detail.